Some sites report that they dont get an "internal server error"
rather when clicking on certain clients from the management
interface, the client page is simply blank.
This is the same problem however, the Web server fails to return the
appropriate message.
Glen.
--- In alltalk-avp@..., "lrs_y_gk_07" <glenk@...>
wrote:
>
>
> Dear all,
>
> With the Beta Trials of Alltalk 1.1.1.80, it has been discovered
that
> the Midas.dll used to render the Entity and Site XML information
into
> HTML tables by the AlltalkWI CGI, are not distributed with the
Alltalk
> Server install.
>
> Problem:
>
> After a client has updated their Organisation and Entity
information and
> uploaded it to the Alltalk server, the client can no longer log
onto the
> Alltalk User Web interface because the user page returns and Interal
> Server error.
>
> The problem is that when the CGI attempts to convert the Entity and
> Organisation XML data into HTML, it expects the Midas.dll
(Borland) to
> be present on the machine. When the dll is missing, the getUser
Action
> has an unrecoverable error which terminates processing of the
request
> and returns an error message to the clients browser.
>
> Resolution.
>
> Get the midas.dll from http://www.galkam.com.au/zipfiles/midas.dll
> <http://www.galkam.com.au/zipfiles/midas.dll> and save it into the
Web
> servers SYSTEM32 folder. The next call to the users web interface
will
> be successful.
>
>
>
> Reproducing this problem:
>
> 1) Update a test client to Alltalk 1.1.1.80 Beta client from
> http://www.lrsupport.com.au/downloads
> <http://www.lrsupport.com.au/downloads>
>
> 2) On the Organisation and People Tab, Click Edit and enter the
> Organisation (Site) information and Some Entity (People)
information.
> Click OK
>
> 3) Fetch files. The alltalk Client will upload the client
information
> to the server.
>
> 4) Access the alltalk Web interface either as Manager or as the
specific
> client user ID.
>
> 5) If the midas.dll is missing, you will see "Internal Server Error"
>